Stancor, Inc. - 'S' Series Electric Submersible Dewatering Pumps
Electric Submersible Pumps
Pump Control Systems
Pump Accessories
Oil Minder Pump Systems
Specialty Pump Coatings /
Protection
Home
Newsletter
Technical Data
About Us
Contact Us
Request Information
Call:
203.268.7513
office@stancorpumps.com
All Categories
>
Pump Accessories
>
Vertical Piggyback Float with Alarm
>
LX Series Submersible Sewage Pumps
>
'S' Series Electric Submersible Dewatering Pumps
>
View Items
Download PDF
Printable Page
Email This Page
Save To Favorites
'S' Series Electric Submersible Dewatering Pumps
Check up to five results to perform an action.
larger image
There are many features common to all Stancor "S" Series pumps. All of these features add up to one thing -
a better pump.
SEALING SYSTEM
S-150 through S-7500 Silicone Carbide vs. Silicone Carbide
S-1500, S-2000, S-3000, S-4500 and S-7500 model pumps are equipped with a wear-resistant seal housing and a stainless steel cartridge-type seal with solid silicone car bide seal faces. This state of the art system can with stand extremely high pressure and utilizes anti-vibration bellows to prevent the seal faces from separating even under the most extreme operating conditions.
The mechanical seals run in an oil filled chamber reducing the chance of overheating and failure.
THERMAL OVERLOAD PROTECTION
Every Stancor "S" unit has two thermal overload klixons wound into the stator. If the pump should over heat for any reason, the overloads shut the pump off automatically.
DISCHARGE LINING/DIFFUSER
Every Stancor "S" series unit has a discharge lining as standard equipment. This lining eliminates wear on the pump housing from abrasive action and is available in a variety of materials such as nitrile, rubber, polyurethane, nylon, etc.
CONTACTOR
The contactor is located in the head of the pump. Klixons are wired directly into the contactor thus elimi nating the need for a contactor in the control box.
IMPELLERS
Standard impellers are made of hardened stainless steel (17-4ph) capable of withstanding both heavy abrasives and chemical attack. Impellers and rotor shafts are keyed and threaded for a double secure fit.
PERFORMANCE
Generally, it can be stated that Stancor "S" series pumps provide more overall efficiency - more gallons per minute (gpm) per horsepower (hp). This allows a customer to use a smaller "S" pump saving money on the unit and subsequent operating costs.
COATING
All Stancor "S" series pumps can be hardcoated and teflon impregnated for extra protection in those extremely harsh operating environments. The process is dramatically effective and economical. Stancor offers other optional coatings for applications. Please view our Coatings section for more details.
PORTABILITY
All Stancor "S" series pumps are lightweight when compared to similar competitive pumps. The slimline design of the pumps facilitates installation in tight quarters.
Results Per Page :
25
50
100
200
Results 1 - 25 of 32
1
2
Model #
Motor Rating
Voltage
Current
RPM
Maximum Volume
Maximum Head
Power Cable
Special Comments
Discharge Stardard Size (NPT)
Impeller Material
S-150 1 phase
1.2 hp
115/230 V
11/4.8 A
3450
150 gpm
58 ft
50', 14/4
Must be used with supplied capacitor start control for 115 V
2"
Stainless Steel
S-150-3 phase
1.5 hp
230/460/575 V
4.8/2.4/1.9 A
3450
150 gpm
58 ft
50', 14/4 MSHA
N/A
2"
Stainless Steel
S-500 HH-1 phase
3 hp
230 V
13.5 A
3450
180 gpm
107 ft
50', 12/4
Must be used with supplied capacitor start control for 230 V
3"
Stainless Steel
S-500 HV-1 phase
3 hp
230 V
13.5 A
3450
325 gpm
68 ft
50', 12/4
Must be used with supplied capacitor start control for 230 V
4"
Stainless Steel
S-500 HH 3 phase
4.6 hp
230/460/575 V
13/6.5/4.8 A
3450
225 gpm
108 ft
50', 12/4
N/A
3"
Stainless Steel
S-500 HV 3 phase
4.6 hp
230/460/575 V
13/6.5/4.8 A
3450
365 gpm
77 ft
50', 12/4
N/A
4"
Stainless Steel
S-750 HH-1 phase
5 hp
230 V
21 A
3450
250 gpm
108 ft
50', 12/4
Must be used with supplied capacitor start control for 230 V
3"
Stainless Steel
S-750 HV-1 phase
5 hp
230 V
21 A
3450
425 gpm
77 ft
50', 12/4
Must be used with supplied capacitor start control for 230 V
4"
Stainless Steel
S-750 HH 3 phase
6.4 hp
230/460/575 V
17.8/8.9/8.6 A
3450
375 gpm
117 ft
50', 12/4
N/A
3"
Stainless Steel
S-750 HV 3 phase
6.4 hp
230/460/575 V
17.8/8.9/8.6 A
3450
475 gpm
80 ft
50', 12/4
N/A
4"
Stainless Steel
S-1000-HH
10 hp
230/460/575 V
35/17.5/14 A
3450
500 gpm
160 ft
50', *10/4
*6/3 G-GC cable for 230 volt applications
3"
Stainless Steel
S-1000-HV
10 hp
230/460/575 V
35/17.5/14 A
3450
750 gpm
120 ft
50', *10/4
*6/3 G-GC cable for 230 volt applications
4"
Stainless Steel
P-60CM-HH
13 hp
230/460/575/950 V
40/20/14/9 A
3450
400 gpm
230 ft
50', 6/3 G-GC
N/A
4"
Stainless Steel
P-60CM-HV
13 hp
230/460/575/950 V
40/20/14/9 A
3450
900 gpm
95 ft
50', 6/3 G-GC
N/A
6"
Stainless Steel
S-2000-HH
18 hp
230/460/575/950 V
49/24.5/15/13 A
3450
400 gpm
300 ft
50', 6/3 G-GC
N/A
4"
Stainless Steel
S-2000-HV
18 hp
230/460/575/950 V
49/24.5/15/13 A
3450
1050 gpm
105 ft
50', 6/3 G-GC
N/A
6"
Stainless Steel
P-70C-HH
28 hp
460/575/950 V
39/30/20 A
3450
425 gpm
380 ft
50', 6/3 G-GC
N/A
4"
Stainless Steel
P-70C-HV
28 hp
460/575/950 V
39/30/20 A
3450
1550 gpm
140 ft
50', 6/3 G-GC
N/A
6"
Stainless Steel
S-4500-HH
45 hp
460/575/950 V
54/42/25 A
3450
425 gpm
460 ft
50', 6/3 G-GC
N/A
4"
Stainless Steel
S-4500-HV
45 hp
460/575/950 V
54/42/25 A
3450
1550 gpm
170 ft
50', 6/3 G-GC
N/A
6"
Stainless Steel
S-7500HH
75 hp
460/575/950 V
86/69/42 A
3450
1400 gpm
330 ft
50', 4/3 G-GC
optional 2/3 G-GC cable
6"
Stainless Steel
S-7500HV
62 hp
460/575/950 V
72/58/35 A
1750
3800 gpm
135 ft
50', 4/3 G-GC
optional 2/3 G-GC cable
10"
Stainless Steel
SW-500-1
4.6 hp
230/460/575 V
12/6/4.8 A
3450
300 gpm
50 ft
50', 12/4
Large Volute and base,2.5" solids cap.
4"
Stainless Steel
SW-500-2
4.6 hp
230/460/575 V
12/6/4.8 A
3450
300 gpm
55 ft
50', 12/4
N/A
3"
Stainless Steel
SW-750-1
6.4 hp
230/460/575 V
12.8/8.9/8.6 A
3450
325 gpm
55 ft
50', 12/4
Large Volute and base,2.5" solids cap.
4"
Stainless Steel
Results 1 - 25 of 32
1
2
Copyright © 2011 Stancor Pumps Inc., All Rights Reserved.
Privacy
|
Sitemap
| Site Created by
ThomasNet Web Solutions
and Powered by
Navigator Platform